SNMP EdgeIO Controller BL193

No.BL193
SNMP edge controller that converts Modbus RTU/TCP data to standard SNMP OIDs. Supports SNMP v1/v2c/v3 with encryption. Built‑in MIB libraries. Expandable with 1-3 Y Series I/O boards. Perfect for data center monitoring, telecom base stations, and IT/OT integration. -40°C to +85°C.
Description

BL193 SNMP EdgeIO Controller

Industrial I/O. Standard SNMP. — Bridge your OT field devices to your IT network management system.


Your IT team asked for SNMP. Your field devices speak Modbus. Now you have a solution.

Your IT department manages everything through SNMP — servers, switches, routers, printers. But your field devices — sensors, meters, actuators — speak Modbus. Getting OT data into your IT network management system usually means custom scripts, proprietary gateways, or unsupported hacks.

The BL193 solves this problem. It is an SNMP edge controller that collects Modbus data from your field devices and exposes it as standard SNMP OIDs. Your existing network management system queries the BL193 like any other SNMP device. No custom development. No unsupported workarounds.

Think of it as your OT-to-SNMP bridge — IT‑friendly, industrial‑grade, and ready to deploy.


What BL193 Does Best

📡 Native SNMP — Enterprise IT Ready

The BL193 is a standard SNMP agent. Supports SNMP v1, v2c, and v3 with encrypted communication. Built‑in standard MIB libraries. Your existing NMS (Nagios, SolarWinds, PRTG, Zabbix, or any SNMP manager) discovers the BL193 and reads OIDs like any other network device. No special plugins. No custom drivers.

🔁 Modbus to SNMP — Automatic Conversion

Collect data via Modbus RTU (RS485) or Modbus TCP. The BL193 automatically maps Modbus registers to SNMP OIDs. Your NMS sees clean, structured data. No scripting. No complex mappings. Just configure and go.

📦 Expandable I/O — Up to 3 Slots for Y Series Boards

Choose 1, 2, or 3 Y Series I/O boards. Local I/O data is also exposed as SNMP OIDs alongside your Modbus device data. Digital, analog, temperature, pulse — all available through SNMP.

🔐 SNMP v3 with Encryption

Enterprise‑grade security. SNMP v3 supports authentication and privacy (encryption). User policy management. Complies with corporate network security policies. Your IT security team will approve.

⚡ Dual Ethernet with Integrated Switch — Line Topology Ready

Two RJ45 ports with built‑in switch support line topology. Daisy‑chain multiple BL193 controllers without an external switch. Less hardware. Simpler cabling.

🌡️ Built for Harsh Environments — -40°C to +85°C Operation

Wide‑temperature operation, electrical isolation, EMC/EMI protection, independent hardware watchdog. The BL193 survives in data center hot aisles, outdoor cabinets, and industrial control panels.

📡 Remote Maintenance — BLRAT Included

Remote firmware upgrades and parameter configuration are built in. Update devices in the field without sending a technician. Reduce downtime. Lower service costs.


Who Should Use BL193?

🏢 Data Center and Server Room Monitoring

Monitor temperature, humidity, power consumption, and access door status in your data center or server room. Existing Modbus sensors connect to BL193 via RS485. BL193 exposes data as SNMP OIDs to your data center NMS. Get alerts when temperature rises or doors open — through your existing IT monitoring system.

📡 Telecom Base Station Monitoring

Remote base stations need environmental monitoring — temperature, humidity, power status, generator fuel level, door contacts. BL193 collects data from Modbus sensors and reports via SNMP to your central NMS. Wide temperature range ensures reliable operation in outdoor cabinets.

🏭 Industrial Network Management

Your IT team manages the industrial network alongside the corporate network. They want SNMP from every device. BL193 gives you SNMP from your field I/O — conveyor status, tank levels, pump running states, alarm conditions. One monitoring system for everything.

🔧 Smart Campus and Facility Management

Monitor HVAC status, lighting control, energy consumption, and security contacts across a campus. Existing Modbus devices connect to BL193. Facility IT team monitors everything through their existing SNMP-based NMS.

⚙️ OEM Equipment with SNMP Requirement

Your customers require SNMP monitoring for your equipment. Your machine uses Modbus internally. Add a BL193 to each machine — it collects internal Modbus data and exposes it via SNMP. Your customers get the monitoring they need. You keep your existing control architecture.


SNMP Versions — Choose Your Security Level

Version Security Best For
SNMP v1 Basic community string, no encryption Legacy systems, internal trusted networks
SNMP v2c Community string, GET/SET support Most modern NMS, better performance than v1
SNMP v3 Authentication + encryption (AES-256), user policies Enterprise networks, security‑conscious IT departments

Technical Specifications 

📋 For complete technical specifications and Y Series I/O board selection, please see the EdgeIO Controller Selection Guide


Ordering Information

Model BL193
Description SNMP EdgeIO Controller, dual RJ45, isolated RS485, 1-3 Y Series I/O slots, web config, SNMP v1/v2c/v3, Modbus to SNMP gateway, -40°C to +85°C
  • snmp i/o module
  • data center
  • network management system
  • snmp io
  • nms
  • snmp i/o

Want to get more information?

REQUEST A QUOTE
IIoT Gateway Manufacturer

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
FirstName*
LastName*
Email*
Message*
Code*
Verification Code
Leave a message
FirstName*
LastName*
Email*
Message*
Code*
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.