BE107 substation automation protocol gateway supports Siemens, Mitsubishi, Omron, Delta PLC protocols, Modbus converting to IEC104 protocol. BE107 is designed for power grids, distribution stations.
Communication
Ethernet, 4G, WiFi
Downlink Protocol
Siemens, Mitsubishi, Omron, Delta PLC protocols, Modbus RTU, Modbus TCP
Uplink Protocol
IEC 104
Serial Port
2CH or 6CH RS485/RS232
Baud Rate
2400bps-115200bps
Ethernet Port
1 WAN + 1 LAN
Description
The PLC to IEC104 protocol gateway is a specialized industrial communication device. Its main function is to implement bidirectional data conversion between various industrial protocols used by programmable logic controllers (PLCs) (such as Modbus RTU/TCP, Siemens, Mitsubishi, Omron, Schneider and other PLC private protocols) and the IEC 60870-5-104 protocol widely used in the field of power system automation.

Key Features

Bidirectional Protocol Conversion

  • Downlink Support: Supports Siemens/Mitsubishi/Omron/Delta PLC and Modbus RTU/TCP master station, seamlessly connecting to mainstream industrial PLC.
  • Uplink Support: IEC 104 (Standard protocol for PV/power systems)

Powerful Edge Computing

  • ARM MCU @300MHz + Linux OS
  • Connect 10/50 devices & collect 512/4000 data points simultaneously
  • Hardware/software watchdog for 24/7 reliability

Flexible Connectivity
  • Dual Ethernet Ports: 1×WAN + 1×LAN (10/100M auto-adaptive), supports cascaded switches
  • Serial Ports: 2 or 6×RS485/RS232 (customizable baud rate/parity)
  • WiFi Option: Dual-band 2.4G/5G support


Typical Applications

Photovoltaic power station: Inverter monitoring + environmental sensor data aggregation (RS485 cascade expansion)
Intelligent distribution room: Centralized management of electric energy meters + IEC104 protocol remote transmission dispatch center
Energy Monitoring: PLC Data Acquisition → Power SCADA Platform


Technical Specifications

Parameter Description
System Processor Clock speed 300Mhz
Storage 128MB
Flash Memory 64MB
Power Supply Input Voltage DC 9~36V 
Power Consumption Normal: 70mA@12V, Max: 168mA@12V
Wiring Anti-reverse connection protection
Ethernet Port Specification 2 x RJ45, 10/100Mbps, adaptive MDI/MDIX
Protection ESD: ±6kV(Contact), ±8kV(Air)
EFT: 1kV, 5kHz
Serial Port QTY 2CH or 6CH RS485/RS232
Baud Rate 2400bps-115200bps
Data Bit 7,8
Parity Bit None, Even, Odd
Stop Bit 1, 2
Protection ESD: ±6kV(Contact), ±8kV(Air)
SURGE  ±1kV, 8/20us
EFT: 1kV, 5kHz
SIM Card Slot QTY 1
Specification Drawer type, support 1.8V/3V SIM/UIM card(NANO)
Protection Built-in 15KV ESD protection
USB Port QTY 1xMini USB
Protection Over current protection
4G
(Optional)
Antenna QTY 1
Antenna Type SMA Hole 
GPS
(Optional)
Antenna QTY 1
Antenna Type SMA Hole
Tracking Sensitivity > -148 dBm
Flat Position Precision 2.5m
Protocol NMEA-0183 V2.3
WiFi
(Optional)
QTY 1
Type SMA
Protocol 802.11a/b/g/n (mixed)
Mode Client Mode
Channel 2.4G Channel 1 - 13,5G Channel 36 - 165
Security Security
Encrypted AES, TKIP, TKIPAES
Speed 150Mbps (Max)
Distance Unobstructed/open outdoor coverage up to 20 meters
SSID broadcast switch Support
Indicator PWR Always on when device powered on 
RUN Flickering when system running
Off when system shutdown
LINK Flickering when Ethernet communication; Always on when 4G or WiFi communication; OFF when Ethernet, 4G, WiFi are all disconnected.
Software Internet Protocol IPV4, TCP/UDP, DHCP, DNS, etc
IP Retrieving Static IP/DHCP
Transparent Transmission Support
DNS Support Domain Name resolution
Configuration PC software configuration, support WIN 7, WIN 8, WIN 10 and WIN11
Network Cache Transmitting: 8Kbyte; Receiving: 8Kbyte
Safety Regulations EMC CE, FCC
EMS IEC 61000-4-2 (ESD) Level 3
IEC 61000-4-4 (EFT) Level 3
IEC 61000-4-5 (Surge)Level 3
Vibration IEC60068-2-6
Environment Working -40~85℃, 5~95% RH
Storage -40~85℃,5~95% RH
Others Housing Material Plastic
Size 40×83×110mm/30×83×110mm (LxWxH)
Protection  IP30
Net Weight 171g/133g
Mounting DIN Rail Mounting/Wall-mounting

Model Selection

Model WAN LAN COM(RS485)
(Optional RS232)
WiFi 4G GPS
BE107 1 1 2 × × ×
BE107L 1 1 2 × ×
BE107LG 1 1 2 ×
BE107W 1 1 2 × ×
BE107P 1 1 6 × × ×
BE107PL 1 1 6 × ×
BE107PLG 1 1 6 ×
BE107PW 1 1 6 × ×


Shipping Packaging

  • Industrial-grade Gateway x1
  • DIN35 mounting bracket x1
  • Connection Terminalsx1
  • WiFi antenna x1 (Optional)
  • Cellular antenna x1(Optional)
  • GPS antenna x1  (Optional)
  • Certificate of conformity x1
  • Warranty card x1
  • PLC to IEC104 Gateway
  • PLC to IEC104 Gateway
  • PLC to IEC104 Gateway
  • PLC to IEC104 Gateway
  • PLC to IEC104 Gateway

Want to get more information?

REQUEST A QUOTE
IIoT Gateway Manufacturer

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
FirstName*
LastName*
Email*
Message*
Code*
Verification Code
Leave a message
FirstName*
LastName*
Email*
Message*
Code*
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.